Safety and Regulations

Safety, Protection and Compliance
Please contact tripti.singh@moixa.com for more details on evidence and test reports
StageMSB- V4 3000 4.8kWh Moixa Smart BatteryComments
PRODUCT DESIGNCE Marked productMarking
CE marked batteries and inverter used
EN 60950-1, IEC 62109-1 and IEC 62109-2 (for EESS)Safety/LVD testing
IEC 62619, UN 38.3, UL 1973 and IEC 60950-1 tested & certified battery modules
UL 1642, IEC 62619 and UN 38.3 tested & certified battery cells used
IEC 62109-1, IEC 62109-2 & IEC 62040-1certified inverters
EN 301 489-1, /EN 301 489-52 Ver. 1.1.0, EN 301 489-17, Ver. 3.2.0EMC testing (batteries and inverters are also tested)
EN 300 328, Ver. 2.1.1RED testing
RoHS & REACHCertification of components and Moixa’s take-back scheme in place for Environmental compliances
WEEE and waste batteries and accumulators’ directive
UK Grid connection ERECs G98 , G99 and G100Requirements for grid connection / type testing
EN 50438- Irish protection settings (for Ireland)
AS/NZS 4777(for Australia)
LiFePO4 chemistry usedConsidered to be very safe amongst all others
MANUFACTURINGCompliance to all regulatory requirements of UK’s factoriesFactory’s compliance, quality and environment management system
ISO 9001:2015
ISO 14001:2015
INSTALLATIONMCS certified installers (for UK)Installer certifications for solar + storage installation
CEC (Clean Energy Council) accredited installers (for Australia),
SEAI registered installers (for Ireland)
Moixa accredited installers (for UK)For storage only installation
Instruction provided through training, manuals, MSDSExperienced and qualified installers contracted
IET Wiring regulation BS 7671 (for UK) 18th editionWiring Regulations
ET 101:2008+A1+A2+A3:2018 National Rules for Electrical Installations (for Ireland)
AS/NZS 3000:2018, Electrical installations (for Australia)
IET Code of Practice for Electrical Energy Storage SystemsBest guides / practices
SEAI Domestic Solar PV Code of practice for installers (for Ireland)
Best Practice Guide for battery storage equipment- Electrical Safety Requirements (for Australia)
OPERATIONSUser manual and Material Safety Data Sheet MSDSInstructions provided to users
Remote monitoring and breakdown maintenance visits Throughout the warranty period (if required)
Periodic inspection and scheduled maintenance recommended to customers is 5 yearsAlso conveyed during demo

Here is Material Safety Data Sheet (MSDS) for V3 2&3kWh Moixa Smart Batteries and V3C 2&3kWh Moixa Smart Batteries.